5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
€500.20 Incl. VAT
ISOCLIMA ISOPOLAR 5/8″ (15.87 mm) single insulated copper pipe for air conditioners and heat pumps, supplied in a 50 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible thermal insulation with high resistance to water vapour diffusion helps prevent surface condensation while supporting reliable HVAC installation.
- Fast delivery across Europe (5-10 business days)
- 30-day returns
- No customs duties within the EU
- Secure payments
ISOCLIMA ISOPOLAR 5/8″ Insulated Copper Pipe For Air Conditioners 50m
Insulated freon pipe designed for refrigerant piping in air conditioning and heat pump installations. Supplied in a 50 m coil, it is suitable for split, multi-split and VRV systems using R32, R410A and R407C refrigerants.
TECHNICAL INFORMATION
- Bare copper pipe size: 15.88 mm (5/8’’)
- Wall thickness: 1 mm
- Total dimensions with insulation: 36.88 mm
- Insulation thickness: 10 mm
- Length: 50m
- Nominal working pressure (ASTM B111M) (MPa): 7.07
- Nominal burst pressure (MPa): 28.28
- Operating temperature range: -80°C + 98°C
COMPATIBLE REFRIGERANTS
These single copper pipe is suitable for the transfer of refrigerant gases such as R407/C, R410/A, and R32.
They are coated with a low-density, closed-cell polyethylene foam sheath of appropriate thickness, treated with an extruded, white, embossed PE-LD outer film, which provides additional mechanical protection and an aesthetically pleasing appearance. The material is non-toxic, odorless, and free from chlorofluorocarbons (CFCs).
The main features of the insulation sheath are excellent flexibility, bendability, and high resistance to water vapor diffusion, preventing condensation on the pipe surface when transporting fluids at temperatures lower than room temperature.
MAIN CHARACTERISTICS
Excellent elasticity, flexibility and high resistance to the diffusion of water vapor, which allows avoiding the formation of condensation on the surface of the pipe, when fluids with temperatures lower than room temperature are transferred inside the pipe.
ISOCLIMA ISOPOLAR Technical Data Sheet
| Weight | 22.33 kg |
|---|---|
| Dimensions | 870 × 870 × 160 mm |
| Package Weight (kg) | 22.3 |
Related products
1/2″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 1/2″ (12.70 mm) insulated copper pipe for air conditioners and heat pumps 25 m. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing supports reliable refrigerant piping while its high resistance to water vapour diffusion helps reduce surface condensation.
1/4” Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
Insulated Copper Pipe 1/4″ (6.35 mm) for Air Conditioners & Heat Pumps 25 m. Suitable for refrigerant line installations in split and VRV air conditioning systems, this flexible insulated copper pipe provides dependable thermal protection and excellent resistance to moisture diffusion. It helps prevent surface condensation while enabling quick installation and reliable long-term performance.
3/4″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 3/4″ (19.05 mm) insulated copper pipe for air conditioners and heat pumps. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing provides reliable refrigerant piping while high resistance to water vapour diffusion helps prevent surface condensation. 25m roll.
3/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 5/8″ (15.88 mm) insulated single copper pipe for air conditioners and heat pumps 25 m. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing provides reliable refrigerant piping, while high resistance to water vapour diffusion helps prevent surface condensation.
ISOCLIMA 1/2” – 3/4” Twin Insulated Copper Pipe for Air Conditioners 20 m
ISOCLIMA BIPOLAR 1/2″–3/4″ (12.70–19.05 mm) twin insulated copper pipe for air conditioners and heat pumps, supplied in a 20 m coil. Designed for refrigerant line installations in split systems and suitable for R32, R410A and R407C refrigerants. Flexible 10 mm closed-cell insulation helps prevent surface condensation and provides reliable thermal and mechanical protection.
ISOCLIMA 1/4″ – 1/2” Twin Insulated Copper Pipe for Air Conditioners 20 m
ISOCLIMA BIPOLAR 1/4″–1/2″ (6.35–12.70 mm) twin insulated copper pipe for air conditioners and heat pumps 20 m. Suitable for R32, R410A and R407C refrigerants, this paired copper pipe provides flexible and reliable refrigerant line installation for split air conditioning systems while helping protect pipework against surface condensation.
ISOCLIMA 3/8″ – 5/8” Twin Insulated Copper Pipe for Air Conditioners 20 m
ISOCLIMA BIPOLAR 3/8″–5/8″ (9.52–15.87 mm) twin insulated copper pipe combines two refrigerant lines for split air conditioning and heat pump installations. Compatible with R32, R410A and R407C refrigerants, its flexible closed-cell insulation provides high resistance to water vapour diffusion, helping reduce condensation on refrigerant pipework. 20m